    Spark Holland Model 900 Triathlon Autosampler
    Actual item displayed. Comes with 30 day money back guarantee. Specs listed below were taken from manufacturers literature.
    GENERAL
    Sound pressure level
    < 70 dB
    Working temperature
    10 – 35 °C
    Storage temperature
    -25 / 60 °C
    Humidity
    20-80% RH
    Installation category
    Category P (according to IEC 1010)
    Pollution degree
    Degree 2 (according to IEC 1010)
    Sample capacity
    96 vials of 1.5 ml (STD), 12 vials per segment
    72 vials of 4.0 ml (LSV), 9 vials per segment
    48 vials of 10ml (Super LSV), 4 vials per segment
    160 micro vials of 0.5 ml, 20 vials per segment
    Vial dimensions
    Maximum vial height: 47 mm inclusive cap.
    Minimum vial height: 32 mm inclusive cap.
    Loop volume
    5 – 1000 µl
    Injection volume
    1µl – 1 ml, with 1 µl increment
    Injections per vial
    max. 9 (Volumes are programmable for each
    injection)
    Injection methods
    Flushed loop injections
    Partial loopfill injections
    µl pick-up injections (without sample loss)
    Needle wash
    Programmable:
    Wash between injections
    Wash between vials
    Wash at end of series
    Wash solvent
    250 ml internal wash solvent bottle
    Dispenser syringe
    100 µl, 250 µl (standard), 500 µl ,1000 µl
    or 10ml (only with userprog)
    Vial detection
    Missing vial detection by vial sensor
    Sample access
    < 10 seconds
    Headspace pressure
    Built-in compressor
    Pre-puncturing septa
    With air needle, dual needle action
    Switching time injection valve
    electrically < 100 msec
    Piercing precision needle
    ± 0.6 mm
    Priority sample
    Free programmable
    ANALYTICAL PERFORMANCE
    Reproducibility
    Capped and sealed vials
    •Full loop injections
    RSD£ 0.3%
    •Partial loopfill injections
    RSD£ 0.5% injection volumes > 5 µl, with
    headspace pressure on the vial and 30µl
    pre-flush with air-segment
    •µl pick-up injections
    RSD£ 1.0% injection volumes > 5 µl, with
    headspace pressure on the vial
    ELECTRICAL
    Power requirements
    115 VAC; ±10%; 50/60 Hz; 250 VA
    230 VAC; ±10%; 50/60 Hz; 250 VA
    Fuses
    For 115 VAC; two 5.0 AT-fuses
    (slow, ¼” x 1¼”, UL/CSA)
    For 230 VAC; two 2.5 AT-fuses
    (slow, 5 x 20 mm, IEC127)
    COMMUNICATION
    Outputs
    Inject marker (Relay & TTL)
    Vial marker (Relay & TTL)
    Labelled vial marker(Relay & TTL)
    Stop I/O (Relay & TTL)
    BCD output (TTL)
    4 Auxiliary outputs (Relay)
    2 Programmable outputs (Relay)
    Alarm output (Relay)
    4 bit time base (TTL)
    Inputs
    Next injection input (TTL)
    Next vial input (TTL)
    Freeze input (TTL)
    Stop I/O (TTL)
    4 programmable inputs (TTL)
    Serial communication port
    RS 232C or Multilink
    Shipping
    Shipping options vary by item. Much of our inventory is too big to ship via any method but freight. For smaller individual items (valves, sensors, fittings, etc), Fed Ex, UPS, or USPS will be used. We use eBay's International Shipping Program when needed.
    Payment
    We only accept Paypal.
    Please contact us if you have any questions.
    Service
    Disclaimers
    If you are not satisfied with your purchase for any reason, please let us know within 30 days of receipt in order to return the item.  Equipment is located in our warehouse in Wichita, Kansas. Shipping measurements and shipping weight are estimated to the best of our knowledge. In most circumstances, the item pictured will be the item you receive. We may use stock photos on listings with multiple items available for sale. Equipment licenses are not transferable.